General Information
High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15A is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.
Features
- Embedded industrial control computer. The main board is based on the CortexTM-A8, the main frequency is 1GHz and the flash memory is 1GB. The booting speed is only 16 seconds. 8.4-inch color screen, windows operating system, intuitive user-friendly interface, touch screen, support for Chinese and English input, easy to operate.
- High-speed thermal printer facilitate field printing of test data.
- Internal integrated power supply, no need for on-site secondary power supply, easy to use. Can provide DC10 ~ 260V adjustable power supply, current is 20A. Arbitrarily set the action voltage of the opening and closing coils, and can be used for low-voltage action test of circuit breaker.
- Equipped with a linear sensor, a rotation sensor, a universal sensor and a bracket, and a special fixed multifunctional joint, the installation is extremely convenient and simple.
- Applicable to all models of domestic and foreign production of SF6 switches, GIS combination appliances, vacuum switches, oil switches.
- Switch action once, get all the data and graphics.
- The host can store 30000 sets of field test data (extensible memory card), real-time clock inside the machine, easy to archive.
- Equipped with U disk interface, can directly save the data to U disk, upload it to the computer for analysis and storage.
- Able to measure 12 metal contacts, 6 main contacts, 6 auxiliary contacts, 6 closing resistor and 3(6) double-end grounded switch at the same time.
- Including enveloping line, through the numeric value of multi switch test (2-10) to generate standard enveloping line, carry out analysis and comparison, the analysis of switch vibration frequency can also be carried out.
- Fully automatic motor energy storage, motor power measurement function.
- Internal anti-interference circuit can meet the reliable use of 800KV substation.
Specifications
Timing measurement | 12 contacts Inherent open (close) time |
Open (close) in phase synchronization | |
Open(close) phase-to-phase synchronization | |
Close (open) bounce time (number of bounce) | |
Test range: 0.01ms to 18000ms, resolution: 0.01ms | |
Double-end grounded switch measurement | 3(6) contacts Inherent open (close) time |
Open (close) in phase synchronization | |
Close (open) bounce time and waveform | |
Velocity measurement | Just open (just close) velocity |
Specified time period (travel or angle) average velocity | |
Velocity measurement range | 1mm sensor 0.01~25.00m/s |
0.1mm sensor 0.001 to 2.50m/s | |
0.5°angle sensor 1 wave cycle / 0.5° | |
Travel measurement | Moving contact travel (travel) |
Contact travel (open distance) | |
Travel overshoot and return (over-travel) | |
Sensor: 50mm, Resolution: 0.1mm | |
360 line sensor: 360º, resolution: 0.5º | |
Optional sensor: 300mm, 1000mm, acceleration sensor | |
Current display | Maximum current 30A, resolution: 0.01A |
Instrument power supply | AC/DC 220V±10%; 50Hz±2% |
DC power output | DC power output: DC20~260V continuously adjustable, DC110V≤30A (short-term), DC220V≤20A (short-term) |
External trigger voltage | AC/DC10-300V, current≤120A |
Isolated switch measurement range | Voltage output: DC10~260V (adjustable); |
Power output time: 0.01-20 seconds (can be set); | |
The maximum acquisition time of the fracture signal is 200 seconds; | |
Measurable fracture open, close time, three phases different period, bounce time and time | |
Measurable fracture open, close time, three phases different period, bounce time and time | |
Host volume | 360*260*170mm |
Operating Environment | -20ºC~+50ºC |