LW8-40.5kV SF6 Circuit Breaker
Introduction:
LW8-40.5 Outdoor HV SF6 circuit breaker is three-phase AC 50Hz outdoor high voltage electrical equipment for
35kV transmission and distribution system control and protection can also be used for opening and closing of
contact breaker and capacitor bank of the occasion, and current transformer can be included for measurement
and protection purposes. Circuit breaker equipped with CT14-type spring operating mechanism. Meet the
national standard GB1984-89 "AC high voltage circuit breakers" and the International Electrotechnical
Commission standards IEC56 publication, "High-voltage AC circuit breaker" requirements.
Features:
1. Breaking performance, arcing time is short, long electrical life at rated voltage continuously breaking 31.5kA
20 times without maintenance, not replacement of sulfur hexafluoride gas.
2. Insulation reliable pressure gauge when the zero-tolerance 40.5kV/10min;
3. mechanical reliability is high, closing ability, can often operate;
4. to open and close without capacitor current 400A renewed;
5. 25, 50 km long cut empty without renewed;
6. simple structure, small size, long period without maintenance.
Our Services
FAQ
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
Global Service
--Wherever you are, VILLE global network will support and provide you with value.
Quick Response
--In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
Introduction:
LW8-40.5 Outdoor HV SF6 circuit breaker is three-phase AC 50Hz outdoor high voltage electrical equipment for
35kV transmission and distribution system control and protection can also be used for opening and closing of
contact breaker and capacitor bank of the occasion, and current transformer can be included for measurement
and protection purposes. Circuit breaker equipped with CT14-type spring operating mechanism. Meet the
national standard GB1984-89 "AC high voltage circuit breakers" and the International Electrotechnical
Commission standards IEC56 publication, "High-voltage AC circuit breaker" requirements.
Features:
1. Breaking performance, arcing time is short, long electrical life at rated voltage continuously breaking 31.5kA
20 times without maintenance, not replacement of sulfur hexafluoride gas.
2. Insulation reliable pressure gauge when the zero-tolerance 40.5kV/10min;
3. mechanical reliability is high, closing ability, can often operate;
4. to open and close without capacitor current 400A renewed;
5. 25, 50 km long cut empty without renewed;
6. simple structure, small size, long period without maintenance.
Rated working voltage V | AC220 | AC380 | DC48 | DC110 | DC220 |
Rated working current A | 3.5 | 2 | 12.3 | 4.6 | 2.3 |
20°C coil resistance | 6.96 | 23.74 | 3.9 | 23.9 | 95.69 |
Normal working voltage range | 65%-120% rated working voltage, the breaking operation is disallowed after 3 times continuous operation at the voltage of less 30%. |
Rated working voltage V | DC220 AC220 |
Rated working current A | 5 |
Normal working voltage range | 85%-110% rated working voltage |
The charging time at rated working voltage S | Less 15 |
Our Services
1. | Pre sale service |
a. | make technical solution |
b. | send quotation, technical data sheet and drawing |
c. | prepare power transmission plan, testing plan,and shipment plan |
2. | In sale service |
a. | supervise the manufacturing schedule totally in accordance with the plan |
b. | send photos to customer during every manufacturing process(hold point) |
c. | inform the customer one week before testinng. |
3. | After sale service |
a. | installation and commissioning, training the workers |
b. | quick response within 12 hours any time |
c. | provide 12 months gurantee period normally. |
FAQ
1. Q: | What is your delivery time ? |
A: | Depend on the type of transformer. |
2. Q: | What is your payment term? |
A: | 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
3. Q: | What kind of starndard you follow? |
A: | IEC, ANSI, CSA, GB, etc |
4. Q: | What kind of supporting documentation you can provide normally |
A: | Quotation,outline drawing,manufacturing plan, quality control plan testing plan, financial report, type test report(KEMA, CESI),reference list,etc |
5. Q: | What is your normal wanrranty period? |
A: | 12 months after transformer operation. |
6. Q: | Can u do installation and commissioningin user's site? |
A: | Yes, we can send our installation team to user's country for service. |
7. Q: | Do you have any experience in this kind of transformer? |
A: | Yes, we can provide reference list for check. |
8. Q: | Are you manufacturer or trading company? |
A: | Manufacturer with own import & export company. |
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
Global Service
--Wherever you are, VILLE global network will support and provide you with value.
Quick Response
--In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!